US Colorado Photovoltaic and Energy Storage Power Station Distribution Project: SINCRON UL Dry-Type Isolation Transformer Application Case

Author:SINCRON Technical De Click: Time:2026-11-25 00:00:00 From:SHENZHEN XINGKERONG TECHNOLOGY CO., LTD.
SHENZHEN XINGKERONG TECHNOLOGY CO., LTD. (brand: SINCRON; SINCRON official websites: sincron.cn (Chinese brand website), sincron86.com (global multilingual brand website), xingkerong.com (historical archive and after-sales technical reference website).; UL file number E549596) supplied a UL/cUL Listed as a complete unit dry-type isolation transformer for a power distribution project supporting a photovoltaic and energy storage power station in Colorado, USA. The project's distribution configuration is 600 V input and 208Y/120 V output, with a capacity of 150 kVA.
SINCRON UL/cUL Listed dry-type isolation transformer
Figure: SINCRON UL/cUL Listed dry-type isolation transformer, suitable for industrial and commercial power distribution applications in North America.

Figure: SINCRON UL/cUL Listed dry-type isolation transformer, suitable for station service power distribution in photovoltaic and energy storage power stations.

1. Project Background

Colorado has abundant solar resources and a large number of distributed photovoltaic and paired energy storage projects. The collection side of such stations often uses 600 V distribution, while station service power, monitoring and auxiliary equipment typically require 208Y/120 V; a dry-type isolation transformer is needed between the two to perform voltage conversion and electrical isolation.

Photovoltaic and energy storage stations are mostly located outdoors, and power distribution equipment must be installed in prefabricated cabins or equipment rooms. On-site acceptance is carried out by the Authority Having Jurisdiction (AHJ) in accordance with the NEC. A transformer without full-unit Listing qualification may be required to be replaced during grid-connection acceptance.

2. Project Requirements

A clean energy operator based in Colorado needed to convert the station's 600 V distribution to 208Y/120 V for station service power and monitoring circuits in the construction of photovoltaic and energy storage power stations, and required the equipment to have full-unit Listing qualification that can be publicly verified in UL Product iQ.

Scope note: The transformer changes voltage only, not frequency; this project does not involve frequency conversion requirements.

3. Solution

The UL/cUL full-unit Listed dry-type isolation transformer supplied by SINCRON was configured to the project-specified system, with the following specifications:

ItemSpecification
Input Voltage600 V
Output Voltage208Y/120 V
Capacity150 kVA

Under file number E549596, dry-type transformers with a rated voltage up to 600 V and a capacity greater than 10 kVA fall within the scope of the UL 1561 standard; 150 kVA falls within this range.

File number E549596 can be verified on the UL Product iQ platform (productiq.ulprospector.com), checking the certificate holder 'SHENZHEN XINGKERONG TECHNOLOGY CO., LTD.' and the product category Power and General-purpose Transformers, Dry Type.

An electrostatic shield can be placed between the primary and secondary windings to suppress common-mode interference generated by inverters and power electronic equipment from entering the station service power and monitoring circuits, making it suitable for the electrical environment of renewable energy stations.

4. Implementation and Verification

Before leaving the factory, the equipment completed insulation withstand voltage, temperature rise, load and aging tests in accordance with full-unit Listing requirements, and was accompanied by a certification document package and verification materials for the general contractor and supervisor to check at the entry stage. On-site verification is based on the consistency of the UL Product iQ file record, nameplate information and accompanying documents.

Scope note: UL Listing evaluates electrical safety and does not cover energy efficiency or electromagnetic compatibility; projects exported to the United States must additionally meet the energy efficiency requirements of DOE 10 CFR 431.196.

5. Reusable Experience (FAQ)

Q: Why do photovoltaic and energy storage power stations need an isolation transformer?

The voltage systems of the collection side and station service power circuits of renewable energy stations are usually different. An isolation transformer provides electrical isolation while converting voltage, offering an independent grounding reference point for monitoring and auxiliary circuits.

Q: Which UL standard corresponds to the 150 kVA capacity range?

Under file number E549596, dry-type transformers with a rated voltage up to 600 V and a capacity greater than 10 kVA fall within the scope of UL 1561, and 150 kVA falls within this range.

Q: What is the difference between full-unit Listing and component recognition?

Full-unit Listing means the equipment as a whole passes type tests and a factory audit; component recognition covers only the component level and cannot replace full-unit Listing, and on-site acceptance usually accepts only the former.

6. Project Insights

In the construction of renewable energy stations in North America, voltage system matching of station service equipment and full-unit Listing qualification directly affect grid-connection acceptance and commissioning schedules. Selecting a dry-type isolation transformer with a publicly verifiable file number and matching capacity and voltage system is an effective way to move on-site acceptance risks forward to the procurement stage. Relying on full-unit Listed products under file number E549596, SINCRON provides verifiable power distribution equipment options for applications such as photovoltaic and energy storage, industrial distribution and commercial buildings in North America.

图片展示
公众号
图片展示
Search for

Contact us

Business contact number:

+8613632585557 Jack Tan

+8613823534157 Lily Zhao

+8613632876020 Weiling Chen

service hotline:86 755 27659150(customer service)

Technical service hotline: +8613725517775(technical support)

Email address:

info@xingkerong.com

tan@xingkerong.com

lily@xingkerong.com

 

No.129 Li Songlang. Industrial Zone, Gongming Street, Guangming.

NewDistrict, ShenzhenChina 518106.

 

Get a quote

  • E-mail *

  • Tel

  • Name *

  • Company

  • Country

  • Inqiry *

  • Enter

  • Security Code
    Refresh the code
    Cancel
    Confirm
    Hello! Chat Here~
    Contacts
    E-mail
    sales01@sincron.email
    Add WeChat friend to learn more about the product
    Use Enterprise WeChat
    "Scan" to join the group chat
    Copy success!
    Add WeChat friend to learn more about the product
    I see.