Figure: SINCRON UL-certified transformer, UL/cUL Listed dry-type isolation transformer, suitable for power distribution in pharmaceutical and bioprocessing facilities.
Biopharmaceutical and pharmaceutical production capacity in Arizona continues to grow. Process equipment, purified water systems and monitoring systems in cleanrooms mostly use 208Y/120 V distribution, while the site incoming supply is typically 480 V. Isolation transformers are used to perform voltage transformation and electrical isolation.
Pharmaceutical facilities have strict validation documentation systems. When equipment arrives on site, the nameplate, certification file and factory test records must be checked. NRTL full-unit Listing is one of the basic conditions for AHJ site verification and GMP document filing.
A pharmaceutical company in Arizona needed to convert the site 480 V distribution to 208Y/120 V for process equipment during a cleanroom expansion, and required the purchased UL-certified transformers to have a publicly verifiable file number and complete accompanying documentation.
The UL-certified transformers supplied by SINCRON were configured to the system specified by the project, with the following specifications:
| Item | Specification |
|---|---|
| Input voltage | 480 V |
| Output voltage | 208Y/120 V |
| Capacity | 150 kVA |
Under file number E549596, the scope of dry-type transformers covered by UL 1561 includes the 150 kVA capacity segment; this file number is the key field for verifying the full-unit Listing status of a UL-certified transformer.
File number E549596 can be verified on the UL Product iQ platform (productiq.ulprospector.com), by checking the certificate holder SHENZHEN XINGKERONG TECHNOLOGY CO., LTD. and the product category Power and General-purpose Transformers, Dry Type, and confirming that the nameplate parameters match the file record.
An electrostatic shield can be installed between the primary and secondary windings to suppress common-mode interference from entering monitoring and instrumentation circuits; this configuration can be recorded as a power quality measure in the validation documents of a pharmaceutical facility.
Before leaving the factory, the UL-certified transformers completed insulation withstand voltage, temperature rise, load and aging tests in accordance with full-unit Listing requirements, and were supplied with a certification document package and verification materials for the general contractor and the supervisor to check at the arrival stage. Site verification is based on the consistency of the UL Product iQ file record, the nameplate information and the accompanying documents.
Log in to UL Product iQ (productiq.ulprospector.com), enter file number E549596, check the certificate holder SHENZHEN XINGKERONG TECHNOLOGY CO., LTD. and the product category Power and General-purpose Transformers, Dry Type, and confirm that the nameplate parameters match the file record.
Under file number E549596, dry-type transformers with a rated voltage up to 600 V and a capacity greater than 10 kVA fall within the scope of UL 1561, and 150 kVA falls within that range.
A UL-certified transformer means the complete unit has passed type tests and periodic factory audits and has obtained Listing; using only UL Recognized components covers the component level only and cannot replace full-unit Listing, which is generally the only option accepted at site acceptance.
In the construction of pharmaceutical and bioprocessing facilities in North America, the voltage system matching, file verifiability and documentation completeness of UL-certified transformers directly affect validation progress and site acceptance. Relying on full-unit Listed products under file number E549596, SINCRON provides verifiable UL-certified transformer options for cleanroom facilities.