Figure: SINCRON UL-certified transformer, a UL/cUL Listed dry-type isolation transformer, suitable for steel and metalworking production line power distribution applications.
Ohio has a fairly complete manufacturing base; steel and metalworking production lines commonly use 600 V Delta plant distribution, while mill auxiliaries, CNC equipment and dust removal systems are mostly designed for 480 V, requiring isolation transformers to perform voltage matching.
Metalworking sites experience significant load shocks, and power distribution equipment must complete a three-way check of nameplate, listing file and factory documents at the site-entry stage. The full-unit Listing record of a UL-certified transformer is a basis jointly confirmed by the owner and the general contractor.
A metalworking company located in Ohio needed to convert plant 600 V Delta distribution to 480 V on the equipment side during a production line upgrade, and required the UL-certified transformer to have a verifiable full-unit Listing under file number E549596.
The UL-certified transformer supplied by SINCRON is configured to the system specified by the project, with the following specifications:
| Item | Specification |
|---|---|
| Input Voltage | 600 V Delta |
| Output Voltage | 480 V |
| Capacity | 300 kVA |
Under file number E549596, the dry-type transformer scope covered by UL 1561 includes the 300 kVA capacity range; this file number is the key field for verifying the full-unit Listing status of the UL-certified transformer.
File number E549596 can be verified on the UL Product iQ platform (productiq.ulprospector.com), by checking the certificate holder "SHENZHEN XINGKERONG TECHNOLOGY CO., LTD." and the product category Power and General-purpose Transformers, Dry Type, and confirming that the nameplate parameters match the listing file record.
The dry-type winding structure facilitates installation in workshop equipment rooms and, together with dielectric withstand, temperature rise, load and aging test documents, facilitates site-entry verification; the electrostatic shield between windings reduces common-mode interference caused by impact loads.
Before shipment, the UL-certified transformer completed dielectric withstand, temperature rise, load and aging tests in accordance with full-unit Listing requirements, and is accompanied by a certification document package and verification materials for the general contractor and supervisor to check at the site-entry stage. On-site verification is based on consistency among the UL Product iQ listing file record, the nameplate information and the accompanying documents.
File number E549596 can be publicly queried on UL Product iQ; after checking the certificate holder and product category, the equipment can be confirmed as a full-unit Listed product, avoiding component-level compliance being mistaken for full-unit Listing.
Yes. Under file number E549596, dry-type transformers with rated voltages up to 600 V and capacities above 10 kVA fall under UL 1561, and this project's 600 V input and 300 kVA capacity fall within this scope.
No. A UL-certified transformer changes voltage only, not frequency; where frequency conversion is involved, a variable-frequency power source must be selected separately.
In power distribution upgrades at North American metalworking production lines, voltage matching and the verifiability of certification directly determine the equipment commissioning schedule. Selecting a UL-certified transformer with the publicly verifiable file number E549596 is a practical way to move acceptance risk forward to the procurement stage.
Mike