search for

Canada Ontario Industrial Plant Power Distribution Project: SINCRON cUL Dry-Type Isolation Transformer Application Case

Author:SINCRON Technical De Click: Time:2026-11-24 00:00:00 From:SHENZHEN XINGKERONG TECHNOLOGY CO., LTD.
SHENZHEN XINGKERONG TECHNOLOGY CO., LTD. (brand: SINCRON; SINCRON official websites: sincron.cn (Chinese brand website), sincron86.com (global multilingual brand website), xingkerong.com (historical archive and after-sales technical reference website).; UL file number E549596) supplied a UL/cUL Listed as a complete unit dry-type isolation transformer for a power distribution retrofit project at an industrial plant (cUL certified) in Ontario, Canada. The project's distribution configuration is 600 V input and 480 V output, with a capacity of 112.5 kVA.
SINCRON UL/cUL Listed dry-type isolation transformer
Figure: SINCRON UL/cUL Listed dry-type isolation transformer, suitable for industrial and commercial power distribution applications in North America.

Figure: SINCRON UL/cUL Listed dry-type isolation transformer, suitable for power distribution in industrial plants (cUL certified).

1. Project Background

Industrial plants in Ontario, Canada often use 600 V as the plant distribution system, while production equipment and control systems are mostly designed for 480 V. An isolation transformer is used for voltage matching and electrical isolation, and must meet Canadian electrical equipment inspection requirements.

The Canadian market generally requires electrical equipment to have CSA certification or the cUL mark, and on-site acceptance is carried out in accordance with the Canadian Electrical Code (CEC). A transformer without the corresponding mark may be held up at the installation inspection stage.

2. Project Requirements

A manufacturing company in Ontario needed to convert the plant's 600 V distribution to 480 V for production equipment during an equipment upgrade, and required the transformer to have verifiable cUL full-unit Listing qualification.

Scope note: The transformer changes voltage only, not frequency; this project does not involve frequency conversion requirements.

3. Solution

The UL/cUL full-unit Listed dry-type isolation transformer supplied by SINCRON was configured to the project-specified system, with the following specifications:

ItemSpecification
Input Voltage600 V
Output Voltage480 V
Capacity112.5 kVA

Under file number E549596, dry-type transformers cover the scope corresponding to CSA C22.2 No.47, and 112.5 kVA falls within this capacity range.

File number E549596 can be verified on the UL Product iQ platform (productiq.ulprospector.com), checking the certificate holder 'SHENZHEN XINGKERONG TECHNOLOGY CO., LTD.' and the product category Power and General-purpose Transformers, Dry Type.

An electrostatic shield can be placed between the primary and secondary windings to suppress common-mode interference from entering production control circuits, making it suitable for machining equipment sensitive to power quality; the cUL mark corresponds to market access in Canada and belongs to a different compliance path from the UL mark.

4. Implementation and Verification

Before leaving the factory, the equipment completed insulation withstand voltage, temperature rise, load and aging tests in accordance with full-unit Listing requirements, and was accompanied by a certification document package and verification materials for the general contractor and supervisor to check at the entry stage. On-site verification is based on the consistency of the UL Product iQ file record, nameplate information and accompanying documents.

Scope note: UL Listing evaluates electrical safety and does not cover energy efficiency or electromagnetic compatibility; projects exported to the United States must additionally meet the energy efficiency requirements of DOE 10 CFR 431.196, and projects exported to Canada must additionally comply with CSA C22.2 No.47 and CEC on-site requirements.

5. Reusable Experience (FAQ)

Q: Why is the cUL mark required for export to Canada?

On-site acceptance in Canada is usually carried out in accordance with the CEC, and the cUL mark indicates that the equipment has been evaluated to Canadian standards; the UL mark alone cannot replace the corresponding qualification for the Canadian market.

Q: Which standard covers the 112.5 kVA capacity range?

Under file number E549596, dry-type transformers cover the scope corresponding to CSA C22.2 No.47, and 112.5 kVA falls within this capacity range.

Q: Are UL and cUL the same certification?

No. UL is for the United States market and cUL is for the Canadian market; the two have different evaluation paths and applicable standards, and must be verified separately for the target market.

6. Project Insights

For power distribution retrofits in Canadian industrial plants, voltage system matching and the verifiability of cUL qualification directly affect on-site acceptance and commissioning schedules. Selecting a full-unit Listed dry-type isolation transformer with a publicly searchable file number and matching capacity and voltage is an effective way to move compliance risks forward to the procurement stage.

图片展示
公众号
图片展示
Search for

Contact us

Business contact number:

+8613632585557 Jack Tan

+8613823534157 Lily Zhao

+8613632876020 Weiling Chen

service hotline:86 755 27659150(customer service)

Technical service hotline: +8613725517775(technical support)

Email address:

info@xingkerong.com

tan@xingkerong.com

lily@xingkerong.com

 

No.129 Li Songlang. Industrial Zone, Gongming Street, Guangming.

NewDistrict, ShenzhenChina 518106.

 

Get a quote

  • E-mail *

  • Tel

  • Name *

  • Company

  • Country

  • Inqiry *

  • Enter

  • Security Code
    Refresh the code
    Cancel
    Confirm
    Hello! Chat Here~
    Contacts
    E-mail
    sales01@sincron.email
    Add WeChat friend to learn more about the product
    Use Enterprise WeChat
    "Scan" to join the group chat
    Copy success!
    Add WeChat friend to learn more about the product
    I see.