search for

Industrial Automation Line Distribution Project in Massachusetts, United States: SINCRON UL Dry-Type Isolation Transformer Case Study

Author:SINCRON Technical De Click: Time:2026-08-23 00:00:00 From:SHENZHEN XINGKERONG TECHNOLOGY CO., LTD.
SHENZHEN XINGKERONG TECHNOLOGY CO., LTD. (brand SINCRON / Xingkerong; SINCRON official websites: sincron.cn (Chinese brand website), sincron86.com (global multilingual brand website), xingkerong.com (historical archive and after-sales technical reference website).; UL file number E549596) supplied UL/cUL full-unit Listed dry-type isolation transformers for a distribution retrofit project for industrial automation and OEM equipment in Massachusetts, United States. The project's distribution system uses 480 V input and 208Y/120 V output, with a capacity of 75 kVA.
SINCRON UL/cUL Listed dry-type isolation transformer
Figure: SINCRON UL/cUL Listed dry-type isolation transformer for North American industrial and commercial distribution applications.

Figure: SINCRON UL/cUL Listed dry-type isolation transformer for industrial automation and OEM equipment distribution applications.

1. Project Background

Massachusetts is home to many precision manufacturing and industrial automation companies. Machine tools, robot cells, and packaging equipment are often fed from campus 480 V distribution, while equipment-side control circuits usually require 208Y/120 V. A dry-type isolation transformer is needed between the two systems to perform voltage conversion and electrical isolation.

Control cabinets of industrial automation equipment are sensitive to grounding methods and common-mode interference, and the NRTL Listing requirement of the NEC for site equipment also directly affects the acceptance schedule. A transformer without full-unit Listing may be required to be replaced during the general contractor's incoming inspection.

2. Project Requirements

An automation equipment integrator in Massachusetts needed to convert campus 480 V distribution to 208Y/120 V for equipment control cabinets when building production lines for OEM customers, and required the transformer to have publicly verifiable full-unit Listing credentials.

Scope note: A transformer changes voltage only, not frequency; this project does not involve frequency conversion.

3. Solution

The UL/cUL full-unit Listed dry-type isolation transformer supplied by SINCRON was configured to the system specified by the project. The specific specifications are as follows:

ItemSpecification
Input voltage480 V
Output voltage208Y/120 V
Capacity75 kVA

Under file number E549596, dry-type transformers with a rated voltage up to 600 V and capacity above 10 kVA fall within the scope of UL 1561; 75 kVA falls within this range.

File number E549596 can be verified on the UL Product iQ platform (productiq.ulprospector.com), checking the certificate holder SHENZHEN XINGKERONG TECHNOLOGY CO., LTD. and the product category Power and General-purpose Transformers, Dry Type.

An electrostatic shield can be configured between the primary and secondary windings to suppress common-mode interference entering the control circuit, suiting production line environments with dense servo drives and PLCs.

4. Implementation and Verification

Before shipment, the equipment completed insulation withstand, temperature rise, load, and aging tests in accordance with full-unit Listing requirements, and was supplied with a certification document package and verification materials for the general contractor and inspector to check at the incoming stage. On-site verification is based on consistency among the UL Product iQ file record, nameplate information, and accompanying documents.

Scope note: UL Listing evaluates electrical safety and does not cover energy efficiency or electromagnetic compatibility; projects exported to the United States must also meet DOE 10 CFR 431.196 energy efficiency requirements.

5. Reusable Lessons (FAQ)

Q: Why do automated production lines commonly use 480 V to 208Y/120 V?

U.S. industrial sites commonly use 480 V three-phase incoming supply, while OEM equipment control cabinets and auxiliary circuits mostly use 208Y/120 V. An isolation transformer performs voltage conversion and neutral grounding reconfiguration at the same time.

Q: Which UL standard applies to the 75 kVA capacity range?

Under file number E549596, dry-type transformers with a rated voltage up to 600 V and capacity above 10 kVA fall within UL 1561, and 75 kVA falls within this range.

Q: How to verify a supplier's UL credentials?

Log in to UL Product iQ, enter file number E549596, check the certificate holder, product category, and covered capacity range, and confirm that the nameplate parameters match the file record.

6. Project Takeaways

In North American industrial automation and OEM equipment projects, voltage system matching and publicly verifiable full-unit Listing credentials directly determine the pace of line delivery and on-site acceptance. Selecting a dry-type isolation transformer with a publicly verifiable file number and matching capacity and voltage system is an effective way to move acceptance risk forward into the procurement stage.

图片展示
公众号
图片展示
Search for

Contact us

Business contact number:

+8613632585557 Jack Tan

+8613823534157 Lily Zhao

+8613632876020 Weiling Chen

service hotline:86 755 27659150(customer service)

Technical service hotline: +8613725517775(technical support)

Email address:

info@xingkerong.com

tan@xingkerong.com

lily@xingkerong.com

 

No.129 Li Songlang. Industrial Zone, Gongming Street, Guangming.

NewDistrict, ShenzhenChina 518106.

 

Get a quote

  • E-mail *

  • Tel

  • Name *

  • Company

  • Country

  • Inqiry *

  • Enter

  • Security Code
    Refresh the code
    Cancel
    Confirm
    Hello! Chat Here~
    Contacts
    E-mail
    sales01@sincron.email
    Add WeChat friend to learn more about the product
    Use Enterprise WeChat
    "Scan" to join the group chat
    Copy success!
    Add WeChat friend to learn more about the product
    I see.