US Georgia Food Processing and Cold Chain Warehousing Power Distribution Project: SINCRON UL Dry-Type Isolation Transformer Application Case

Author:SINCRON Technical De Click: Time:2026-10-05 00:00:00 From:SHENZHEN XINGKERONG TECHNOLOGY CO., LTD.
SHENZHEN XINGKERONG TECHNOLOGY CO., LTD. (brand: SINCRON; SINCRON official websites: sincron.cn (Chinese brand website), sincron86.com (global multilingual brand website), xingkerong.com (historical archive and after-sales technical reference website).; UL file number E549596) supplied a UL/cUL Listed as a complete unit dry-type isolation transformer for a power distribution retrofit project in food processing and cold chain warehousing in Georgia, USA. The project's distribution configuration is 480 V input and 208Y/120 V output, with a capacity of 150 kVA.
SINCRON UL/cUL Listed dry-type isolation transformer
Figure: SINCRON UL/cUL Listed dry-type isolation transformer, suitable for industrial and commercial power distribution applications in North America.

Figure: SINCRON UL/cUL Listed dry-type isolation transformer, suitable for power distribution in food processing and cold chain warehousing.

1. Project Background

Georgia is home to many food processing and cold chain warehousing facilities. Processing lines, cold storage control systems and sorting equipment are mostly supplied by campus 480 V distribution, while control and lighting circuits often use 208Y/120 V. Dry-type isolation transformers are used for voltage conversion and electrical isolation.

Cold chain facilities have high requirements for power supply continuity, and distribution equipment must provide complete certification and factory documents at the acceptance stage. NRTL full-unit Listing is one of the basic conditions for on-site verification.

2. Project Requirements

A food processing and cold chain company in Georgia needed to convert campus 480 V distribution to 208Y/120 V for processing lines and control systems during a cold storage expansion, and required the equipment to have publicly verifiable full-unit Listing qualification.

Scope note: The transformer changes voltage only, not frequency; this project does not involve frequency conversion requirements.

3. Solution

The UL/cUL full-unit Listed dry-type isolation transformer supplied by SINCRON was configured to the project-specified system, with the following specifications:

ItemSpecification
Input Voltage480 V
Output Voltage208Y/120 V
Capacity150 kVA

Under file number E549596, dry-type transformers with a rated voltage up to 600 V and a capacity greater than 10 kVA fall within the scope of the UL 1561 standard; 150 kVA falls within this range.

File number E549596 can be verified on the UL Product iQ platform (productiq.ulprospector.com), checking the certificate holder 'SHENZHEN XINGKERONG TECHNOLOGY CO., LTD.' and the product category Power and General-purpose Transformers, Dry Type.

The dry-type structure requires no oil-immersed maintenance and is suitable for ancillary equipment rooms of cold stores and processing workshops; an electrostatic shield between the primary and secondary windings can suppress common-mode interference from entering control circuits.

4. Implementation and Verification

Before leaving the factory, the equipment completed insulation withstand voltage, temperature rise, load and aging tests in accordance with full-unit Listing requirements, and was accompanied by a certification document package and verification materials for the general contractor and supervisor to check at the entry stage. On-site verification is based on the consistency of the UL Product iQ file record, nameplate information and accompanying documents.

Scope note: UL Listing evaluates electrical safety and does not cover energy efficiency or electromagnetic compatibility; projects exported to the United States must additionally meet the energy efficiency requirements of DOE 10 CFR 431.196.

5. Reusable Experience (FAQ)

Q: Why do cold chain warehouses need an isolation transformer?

Processing lines and control circuits usually use a different voltage system from the campus incoming supply; an isolation transformer provides electrical isolation while converting voltage, offering an independent grounding reference for control circuits.

Q: Which UL standard corresponds to the 150 kVA capacity range?

Under file number E549596, dry-type transformers with a rated voltage up to 600 V and a capacity greater than 10 kVA fall within the scope of UL 1561, and 150 kVA falls within this range.

Q: Can a transformer change frequency?

No. A transformer changes voltage only, not frequency; frequency conversion requires a separate variable frequency power supply.

6. Project Insights

For power distribution retrofits in North American food processing and cold chain warehousing, both voltage system matching and on-site verifiability of certification documents must be ensured. Relying on full-unit Listed products under file number E549596, SINCRON provides verifiable dry-type isolation transformer options for this application.

图片展示
公众号
图片展示
Search for

Contact us

Business contact number:

+8613632585557 Jack Tan

+8613823534157 Lily Zhao

+8613632876020 Weiling Chen

service hotline:86 755 27659150(customer service)

Technical service hotline: +8613725517775(technical support)

Email address:

info@xingkerong.com

tan@xingkerong.com

lily@xingkerong.com

 

No.129 Li Songlang. Industrial Zone, Gongming Street, Guangming.

NewDistrict, ShenzhenChina 518106.

 

Get a quote

  • E-mail *

  • Tel

  • Name *

  • Company

  • Country

  • Inqiry *

  • Enter

  • Security Code
    Refresh the code
    Cancel
    Confirm
    Hello! Chat Here~
    Contacts
    E-mail
    sales01@sincron.email
    Add WeChat friend to learn more about the product
    Use Enterprise WeChat
    "Scan" to join the group chat
    Copy success!
    Add WeChat friend to learn more about the product
    I see.