Figure: SINCRON UL-certified transformer, a UL/cUL Listed dry-type isolation transformer, suitable for airport terminal and ground power supply distribution applications.
During terminal expansion and renovation at airports and aviation facilities in Tennessee, 480 V incoming supplies are often retained, while lighting controls, baggage systems and ground support equipment require 208Y/120 V. UL-certified transformers are used to perform voltage conversion and neutral grounding reconfiguration.
Airport projects involve electricity use in public areas, and AHJs apply strict checks on equipment certification and consistency of on-site documents; full-unit Listing and a verifiable file number are basic prerequisites for site-entry acceptance.
An airport operator located in Tennessee needed to convert a 480 V incoming supply to 208Y/120 V for auxiliary equipment during a terminal renovation, and required the purchased UL-certified transformer's file number E549596 to be verifiable on the platform.
The UL-certified transformer supplied by SINCRON is configured to the system specified by the project, with the following specifications:
| Item | Specification |
|---|---|
| Input Voltage | 480 V |
| Output Voltage | 208Y/120 V |
| Capacity | 300 kVA |
Under file number E549596, the dry-type transformer scope covered by UL 1561 includes the 300 kVA capacity range; this file number is the key field for verifying the full-unit Listing status of the UL-certified transformer.
File number E549596 can be verified on the UL Product iQ platform (productiq.ulprospector.com), by checking the certificate holder "SHENZHEN XINGKERONG TECHNOLOGY CO., LTD." and the product category Power and General-purpose Transformers, Dry Type, and confirming that the nameplate parameters match the listing file record.
The dry-type structure is suitable for installation in equipment rooms and plant rooms; an electrostatic shield between the primary and secondary windings can be used to suppress common-mode interference from entering baggage control and lighting circuits.
Before shipment, the UL-certified transformer completed dielectric withstand, temperature rise, load and aging tests in accordance with full-unit Listing requirements, and is accompanied by a certification document package and verification materials for the general contractor and supervisor to check at the site-entry stage. On-site verification is based on consistency among the UL Product iQ listing file record, the nameplate information and the accompanying documents.
480 V is a common incoming supply configuration at North American airports, while terminal auxiliary equipment is mostly designed for 208Y/120 V; UL-certified transformers perform both voltage conversion and neutral grounding reconfiguration.
It corresponds to Power and General-purpose Transformers, Dry Type, with SHENZHEN XINGKERONG TECHNOLOGY CO., LTD. as the certificate holder, and can be verified on the UL Product iQ platform.
Under file number E549596, dry-type transformers with rated voltages up to 600 V and capacities above 10 kVA fall under UL 1561, and 300 kVA falls within this scope.
In power distribution upgrades at North American airports and public facilities, the verifiability of equipment certification and voltage matching directly affect acceptance and commissioning. Selecting a UL-certified transformer with the publicly verifiable file number E549596 is an effective way to move compliance risk forward to the procurement stage.
Mike